8-12. INSTALL PHOTO EYE SAFETY SYSTEM
MOUNTING THE PHOTO EYE SENSOR BRACKETS TO WALL:
Locate the mounting position for brackets photo eye beam will
have a clear path from one side of door to other side.
After mounting, the photo eye beam must have a clear path
from one side of the door to the other.
Use the bracket mounting holes as a template to locate an drill (2)
3/16" diameter pilot holes on both sides of the garage door as shown
in Fig. 29.
Secure the bracket with 1/4" x 1-1/2" lag screws provided as shown
in Fig. 29.
MOUNTING THE PHOTO EYE SENSORS TO MOUNTING
BRACKET. Fig. 30
Install the sensors to the mounting bracket by inserting bend
clips of sensor bracket through the vertical slot on mounting
bracket.
Insert straight clips through other set of vertical slot on the mounting
bracket.
Twist one of the straight clips slightly to lock the sensor in place
once inserted through vertical slot on the mounting bracket.
Repeat the above procedure for the other sensor.
To provide the maximum amount of protection, the photo eye
sensors must be mounted between 3.5” and 5” (90-125mm)
above the floor. See Fig. 29.
SENSOR PROTECTION Fig. 32
Before performing maintenance work in garage, such as,
power washing, painting, and other tasks; protect sensors
with provided sensor caps.
ROUTE WIRES Fig. 31
Route wires along wall use staples (not provided) to secure
wiring to wall. Do NOT punch wire. Drive staples with only
enough force to hold wiring in place.
Be sure the wiring is routed away from all moving parts of
door and rail.
Run wires along the top of the rail assembly and secure
them in wire holders.
Fig. 30
Fig. 29
Wall Stud
Lag Screws
Mounting Bracket
3.5” to 5” (90-125mm)
from floor
Sensor Bracket
Mounting Bracket
To Terminal 2
To Terminal 1
Mounting
on garage
floor
Twist Clip
Fig. 32
Photo Eye Sensor
Sensor Cap Protector
1/4” x 1-1/2”
Fig. 33
Receiver
Transmitter
Transmitter
Receiver
DUAL DOOR INSTALLATION Fig. 33
In dual door installations, the transmitter (TX) and the receiver
(RX) photo eye sensors (as marked on each of the photo eye
components) should be mounted as indicate in Fig. 31. TX
and RX marks located on the back side of the transmitter
and receiver.
Wire Holder
Fig. 31